Lab Capabilities

 10 m Compliant Semi-Anechoic Chamber (up to 3 m, 4,000 kg EUT)
 3 m Compact Full Anechoic Chamber
 Shielded Room for Conducted Emission and Immunity tests
 Shielded Room for ESD tests
 Caters up to 40 prescribed test standards
 40GHz CISPR 16-1-1 Compliant EMI Test Receivers

 Max EUT size: 3 m, 4,000 kg
 Radiated Emissions Frequency Range: 30 MHz — 40 GHz
 Radiated Immunity Frequency Range: 80 MHz — 18 GHz
 Field Uniformity: Comply with IEC 61000-4-3
 Emission measurement (NSA): ANSI C63.4 and CISPR 16 30 MHz — 1 GHz
 SVSWR: Comply with CISPR 16-1-4, 1 — 18 GHz
 Shielding: 100 dB up to 40 GHz

 EUT diameter: 1.5 m
 Radiated Emissions Frequency Range : 30 MHz — 18 GHz
  (Pre-compliance)
 Radiated Immunity Frequency Range: 80 MHz — 18 GHz
 Field Uniformity: Comply with IEC 61000-4-3
 Shielding: 100 dB up to 18 GHz
 SVSWR: Comply with CISPR 16-1-4, 1 — 18 GHz
 Shielding: 100 dB up to 40 GHz

 

MC Test Standards

Standard Compliance                                                  

IEC / ISO 17025
EMC directive 89/336/EWG (CE) or 2004/108/EC
EC directive 72/245/EWG revised of 95/54/EG (e1)

 

CE Mark is a mandatory conformity mark on many products placed on the single market in the European Economic Area.
All commercial electronic devices (unintentional radio-frequency radiators) sold in the United States are regulated by the Federal Communications Commission (FCC).

 

Planned Test Standards

Radiated Emission (RE)/Conducted Emission (CE) Standards

EN55011 Industrial, Scientific, Medical (ISM)
EN55022 Information Technology Equipment (ITE)
EN61000-3-2 Limits for Harmonic Current Emissions
EN61000-3-3 Limitation for Voltage Changes & Flicker
EN61000-6-3 (Generic) Residential, Commercial, Light-Industry
EN61000-6-4 (Generic) Industry
EN61326-1 Electrical Equipment for Measurement, Control and Laboratory Use
EN50366 Household and Similar Electrical Appliances
EN55013 Broadcast Receivers and Associated Equipment
EN55014 Household Appliances
EN300 086 Analogue Speech Radio
EN300 113 Radio Equipment Intended for the Transmission of Data
EN300394-1 TETRA Radio
EN300219 Land Mobile Service; Radio Equipment Transmitting Signals to Initiate a Specific Response in the Receiver

Radiated Immunity (RI) / Conducted Immunity (CI) Standards                                      

EN 61000-4-2   ESD
EN 61000-4-3 Radiated Immunity
EN 61000-4-4 EFT/B
EN 61000-4-5 Surge
EN 61000-4-6 Conducted RF
EN 61000-4-8 Power Frequency Magnetic
EN 61000-4-11 Voltage Dips & Interruptions
EN 61326-1 Electrical Equipment for Measurement, Control and Laboratory Use
EN 55020 Sound, TV Broadcast Receivers and Associated Equipment
EN 301 489-1 Radio Equipment - General Requirement
EN 301 489-18 TETRA Radio Equipment
EN 301 489-5 Analogue Speech Radio Equipment
EN 55024 Information Technology Equipment (ITE)
EN 61000-6-1 (Generic) Residential, Commercial and Light-Industry
EN 61000-6-2 (Generic) Industry

Automotive (E-Marking) Component Level or ESA
Emission Standards                                                                          

CISPR 2 Limits & Methods of Measurement of Radio Disturbance Characteristics for the Protection of Receivers Used on Board Vehicles
ISO 7637-2DC Transient & Surge

Immunity Standards                                                                    

ISO 11452 Road Vehicles   Component Test Methods for Electrical Disturbances
ISO 7637-2DC Transient & Surge

Federal Communications Commission (FCC)                                                                                                                              

FCC Parts 15, Subpart B, Revision 2008
FCC Parts 15, Subpart C, ANSI C 63.4
FCC Part 18  
FCC Part 25
FCC Part 90, TIA 603